( ! ) Notice: Trying to access array offset on value of type null in /home2/sakaka/public_html/web/header.php on line 108
Call Stack
#TimeMemoryFunctionLocation
10.0001363952{main}( ).../product-detail.php:0
20.0001364504include( '/home2/sakaka/public_html/web/header.php ).../product-detail.php:1

( ! ) Notice: Trying to access array offset on value of type null in /home2/sakaka/public_html/web/header.php on line 116
Call Stack
#TimeMemoryFunctionLocation
10.0001363952{main}( ).../product-detail.php:0
20.0001364504include( '/home2/sakaka/public_html/web/header.php ).../product-detail.php:1

( ! ) Notice: Trying to access array offset on value of type null in /home2/sakaka/public_html/web/header.php on line 117
Call Stack
#TimeMemoryFunctionLocation
10.0001363952{main}( ).../product-detail.php:0
20.0001364504include( '/home2/sakaka/public_html/web/header.php ).../product-detail.php:1

( ! ) Notice: Trying to access array offset on value of type null in /home2/sakaka/public_html/web/header.php on line 118
Call Stack
#TimeMemoryFunctionLocation
10.0001363952{main}( ).../product-detail.php:0
20.0001364504include( '/home2/sakaka/public_html/web/header.php ).../product-detail.php:1

( ! ) Notice: Trying to access array offset on value of type null in /home2/sakaka/public_html/web/header.php on line 123
Call Stack
#TimeMemoryFunctionLocation
10.0001363952{main}( ).../product-detail.php:0
20.0001364504include( '/home2/sakaka/public_html/web/header.php ).../product-detail.php:1

( ! ) Notice: Trying to access array offset on value of type null in /home2/sakaka/public_html/web/header.php on line 124
Call Stack
#TimeMemoryFunctionLocation
10.0001363952{main}( ).../product-detail.php:0
20.0001364504include( '/home2/sakaka/public_html/web/header.php ).../product-detail.php:1

( ! ) Notice: Trying to access array offset on value of type null in /home2/sakaka/public_html/web/header.php on line 125
Call Stack
#TimeMemoryFunctionLocation
10.0001363952{main}( ).../product-detail.php:0
20.0001364504include( '/home2/sakaka/public_html/web/header.php ).../product-detail.php:1

( ! ) Notice: Trying to access array offset on value of type null in /home2/sakaka/public_html/web/header.php on line 126
Call Stack
#TimeMemoryFunctionLocation
10.0001363952{main}( ).../product-detail.php:0
20.0001364504include( '/home2/sakaka/public_html/web/header.php ).../product-detail.php:1

( ! ) Notice: Trying to access array offset on value of type null in /home2/sakaka/public_html/web/header.php on line 127
Call Stack
#TimeMemoryFunctionLocation
10.0001363952{main}( ).../product-detail.php:0
20.0001364504include( '/home2/sakaka/public_html/web/header.php ).../product-detail.php:1
HACH, - Alat Lab, Water Analysis, Microbiology - PT. Sumber Aneka Karya Abadi

Sumber Aneka Karya Abadi - Your trusted partner for laboratory instrument

Search

HACH, Intellical™ CDC401 Field 4-Poles Graphite Conductivity Cell, 15 m Cable

Prod #CDC40115

IntelliCAL™ CDC401 merupakan probe digital, dengan panjang kabel 15 meter kabel  terbuat dari stainless steel,  dan dirancang khusus untuk penggunaan dilapangan.  Probe CDC401 sangat cocok untuk mengukur konduktivitas Listrik, Salinitas, Resistivitas, atau Total Padatan Terlarut pada air limbah, air minum, atau aplikasi kualitas air pada umumnya. Digunakan pada seri HQD meter portabel dan benchtop

Product Overview

Spesifikasi :

Accuracy:Cond: ±0.5% of range
 Salinity: ±0.1, ±1 digit
 TDS: ±0.5% ±1 digit
Cable Length:15 m (49.21 ft)
Electrode Type:Conductivity Cell;
4 Poles - Graphite
Kit?:No
Length:223 mm (8.73 in.)
Method Type:Field: 4 Poles - Graphite
Parameter:Conductivity
Probe Type:Rugged
Product Kit:Model: CDC401
Accessories Included: None
Range:0.0 µS/cm to 200 mS/cm
 Conductivity: 0.0 µS/cm - 200 mS/cm
TDS: 0.00 mg/L - 50.0 g/L as NaCl
Salinity: 0 - 42 ppt or ‰
Resistivity: 2.5 Ωcm - 49 MΩcm
Reference Junction:NA
Resolution:0.01/0.1 (5 digits max.)
Sample depth:45 mm (1.77 in.)
Sensor Body Material:Noryl / Stainless Steel
Sensor Cable Length (m):15
Sensor material:Noryl / Stainless Steel
Sensor Type:4-poles conductivity probe, Graphite, k = 0.40 cm-1
Temperature Accuracy:±0.3 °C (±0.54 °F)
Temperature Range:-10 - 110 °C (14 - 230 °F)
Temperature Resolution:0.1 °C (0.18 °F)
Test Requirements:Parameter Needed: Conductivity
Minimum Sample Depth (mm): 45
Thermistor:ATC
Type of Measurement:Field
Water Resistance:IP67, waterproof for 24 hours at a depth of 30 meters
Weight:1.5 kg
 included: Intellical CDC401 Rugged Conductivity Cell, 15 m cable, protective shroud kit, Test certificate, and Basic User Manual.