TU5400sc Ultra-High Precision Low Range Laser Turbidimeter menggunakan metode ISO7027-1dan sempurna untuk aplikasi filtrasi membran. TU5400 menggunakan design optik yang dipatenkan , mengukur lebih banyak sampel dari pada turbiditimeter lainnya, memberikan presisi dan sensitifitas terbaik untuk pengukuran kekeruhan level rendah dengan meminimalisasi variabilitas antar pengukuran. TU5400sc Ultra-High Precision Low Range Laser Turbidimeter dapat menghilangkan nilai ketidakpastian karena menggunakan Detection Tecnology 360º x 90º Detection Tecnology dan memliki respon lebih dari 15 kali lebih cepat daripada FT660. Dengan kemampuan mengukur hingga 0,0002 NTU, TU5400 memberikan standar berikutnya dalam evolusi kekeruhan.
Accuracy : ±2% of reading plus 0.01 NTU from 0 - 40 NTU
Cable Length : 1.6 m (5.25 ft), extendable up to 50 m (164 ft) for instrument without accessories
Calibration Method : For Formazin and Stablcal®:
20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range
Custom calibration for up to 6-point calibrations
Certifications : CE compliant
US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version
Complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
Australian ACMA Marking
Communication : None
Controller : Sensor Only
Dimensions (H x W x D) : 249 mm x 268 mm x 190 mm
Enclosure Rating : Electronic compartment IP55; all other functional units IP65 with process head/ACM attached to the TU5300sc/TU5400sc instrument
Fitting Type : Sample quick connector: ¼-in. for ¼-in. tubing
Light Source : Class 2 laser product, with embedded 650 nm (EPA) or 850 nm (ISO), max. 1.0 mW Class 2 laser source (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
Lower Limit of Detection (LOD) : 0.0001 FNU
Material : ASA Luran S 777K / RAL7000, TPE RESIN Elastocon® STK40,
Thermoplastic Elastomer TPS-SEBS
Model :TU5400sc
Mounting Configurations : Wall Mount
Operating Humidity : elative humidity: 5 - 95% at different temperatures, non-condensing
Operating Temperature Range : - 50 °C (32 - 122 °F)
Options : Process Head Only
Range : ISO:
0 - 1000 NTU / FNU / TE/F / FTU
0 - 250 EBC
Regulatory : I SO
Repeatability : Better than 1% of reading or ±0.0006 NTU on Formazin at 25 °C (77 °F), whichever is greater
Resolution : 0.0001 NTU / FNU / TE/F / FTU / EBC
Response Time : T90 <30 seconds at 100 mL/min
Sample Flow Rate : 100 - 1000 mL/min; optimal flow rate: 200 - 500 mL/min
Sample Pressure : 6 bar (87 psi) maximum, compared to air at sample temperature range from 2 - 40 °C (35.6 - 104 °F)
Sample Temperature : 2 - 60 °C (35 - 140 °F)
Signal Average Time : 1 - 90 seconds
Storage Conditions : -40 - 60 °C (-40 - 140 °F)
Stray Light : <10 mNTU
Units : NTU, FNU, TE/F, FTU, EBC
Verification : Liquid: Stablcal®, Formazin (0.1 - 40 NTU)
Dry: Glass Rod at <0.1 NTU
Weight : 5.95 lbs. (2.7 kg); 11 lbs. (5.0 kg) with all accessories